home  /  Multimedia / Instructions for the operation of the air conditioner Daikin control panel. Instructions for Daikin air conditioners, split systems, consoles

Instructions for the operation of the air conditioner Daikin control panel. Instructions for Daikin air conditioners, split systems, consoles

The Japanese company Daikin, engaged in the production of climate machinery and thermal equipment, goes to leading positions among the other manufacturers of this commercial sector. Why Daikin air conditioners are recognized as the best for which specifications And additional options?

Why Daikin: 3 Reasons

First, this company has all the equipment is divided into domestic, commercial and industrial.

The household section includes mainly split and multi-split systems, which, thanks to new implemented technologies, maximize the accommodation conditions in apartments, residential buildings or in small offices and shops.

Commercial equipment is represented by a very large model range of technical solutions for restaurants, hotels, banks, sports institutions and similar organizations. These include chillers, fan coils, VRV systems and class of Sky-AIR air conditioners with wall, channel, cassette and sub-combine types of internal blocks.

Daikin industrial air conditioners include such equipment as VRV with inverter control, modular systems with the possibility of air conditioning integration, industrial capacitors, precision air conditioners, chillers and other high-performance configurations. They are used in various industries and agriculture, where technological cooling / heating objects have large areas and complex architectural solutions, as well as require the right organization of the microclimate to maintain the "life" of production facilities and compensation for significant inspection.

Secondly, many manufacturers have no additional options that Daikin offers. For example, her new splits possess unique system Air Processing URURU Sarara, which exercises moisturizing without additional water supply, and drainage without cooling, which makes the climate of the room comfortable at any given temperature. In fact, it is air conditioning with a built-in moisturizer and air purifier.

Thirdly, this Japanese manufacturer has entire series of only outdoor blocks of Daikin air conditioners or only internal. This is due to the fact that the device of instruments of this climate technology is very "flexible", so they can be combined with each other from different series. This fact significantly expands the boundaries of the consumer choice and gives more opportunities when designing objects.

Types of air conditioners Daikin.

The proposal of the typical series is worthy: Split with various types of internal blocks, the so-called "cartoons", VRV with the possibility of connecting up to 20 internal apparatuses, fan coils, chillers, roof air conditioners and other types of air conditioning systems.

This article discusses the most popular and demanded air conditioners Daikin, which can be bought in Russia.

Wall systems Daikin.

Splits with the wall internal block are distinguished by their nontrivial design. Aesthetic contours and lines corresponding to the trends of modern style directions were embodied into the curved panel. Original color gamas, compact forms, wide dampers - all these qualities have split systems of the Emura series, Sky Inverter, Urura Sarara.

This wall-mounted equipment belongs to the premium class, so the optional saturation and technical characteristics of the air conditioning Daikin wall type are impressive:

  • high performance in combination with reasonable energy efficiency due to the rotational compressor in most of the models and energy-saving functions - filter auto-cleaning and 2-zone presence sensor;
  • new Safe refrigerant R32;
  • advanced operating temperature range;
  • noise level maximum up to 19 dBA;
  • double air intake and bulk air flows;
  • 5 air treatment methods - moisturizing, drainage, ventilation, cleaning, heating / cooling;
  • oNLINE controller to control air conditioning via the Internet or telephone.

Minimal energy consumption, excellent performance and reduced carbon dioxide emissions - this is what the standard gives wall Split from Daikin.

Cassette systems Daikin

The external block of the cassette air conditioner Daikin is located outside, and the inner with all communications is masked under hinged or false ceiling. In the review zone there remains only a decorative distribution grille, fixed in a single plane along the ceiling line. This is the perfect solution for rooms from 40 m² to 150 m², as well as where hard savings are required when connected.

Semi-industrial (Sky class) Cassette air conditioners Daikin, such as Series FHYC, FCQ, FFQ and FFQ, FFQ, and FHYK, use good demand among buyers. And this:

  • power that makes it possible to quickly reach specified parameters air;
  • low noise;
  • antibacterial surface of the remote control;
  • the ability to combine them in Twin, Triple or Double Twin systems;
  • automatic mode selection and restart;
  • protection against limit temperatures;
  • fresh air submers;
  • powerful filtration system;
  • mandatory condensate removal;
  • economical night mode work;
  • self-diagnostic function for faults;
  • the function of accounting weather conditions;
  • lack of ceiling contamination due to the special algorithm for moving dampers.

Many buyers unanimously believe that Cassette air conditioners are Daikin - this is a stylish climate technique that optimizes the conditions for finding people in various public premises, as well as completely controlled settings for creating comfort.

Ceiling systems Daikin.

The perfect room for the ceiling air conditioner Daikin should have an area of \u200b\u200bup to 150 m² and the ceiling height of up to 4 m. Such structures are placed as follows: the device itself is fixed under the ceiling, and the communications are masked. This is also a SKY class technique.

Usually, follow-up air conditioners Daikin are available from 1, 2, 3 or 4-flow internal block. The choice of streams depends on the form of the room and the location of the device itself. FHY and FHQ series distribute air in one direction, and FUY and FUQ - two, three or four. First, air masses are closed through the grille in the front panel, and then along the ceiling go to the room. In order for the damper to rock in the right direction, it is necessary to ask it the height of the ceiling with a remote control.

In addition, the ceiling air conditioners Daikin possess other advantages:

  • inverter technology that reduces noise and increases energy saving;
  • submerse oxygen;
  • efficient air distribution vertical and horizontal;
  • automatic maintenance of the permissible level of humidity;
  • anti-flap processing of the filter;
  • economical mode of operation in the absence of people indoors with a rapid refund to recreate comfortable conditions when they appear;
  • protection of the heat exchanger of the outdoor unit from Inea;
  • condensate rise by means of drainage pump.

Ceiling air conditioning systems can also operate in multi-split and VRV systems as their components.

This is the perfect working atmosphere without harm to the environment and effective energy saving for many years.

Daikin channel systems

With the help of channel air conditioners Daikin, huge areas (up to 250 m²) of one or more rooms can be cooled. This will require only one external block to which several internal connections are connected. The latter are sewn under the finishing ceiling or stench, making the installation completely inconspicuous.

Channels, through which the cold air goes, heat them to heat them (to eliminate condensate formation) and noise insoloculate. This type has the possibility of a substitution of fresh air through an extensive network of air ducts - up to 30% of the total volume of air mass.

Daikin air-conditioners with a channel indoor unit are distinguished by 3 categories:

  • low-profrans - with pressure up to 40 Pa, handle small rooms with high noise requirements (FDX series);
  • average - with a pressure of up to 100 pa, process larger rooms, have noise levels up to 29 dBA due to aerodynamic noise in the channel (FBQ series);
  • high-pressure - with a pressure of up to 250 Pa, with a capacity of up to 26 kW in heating mode and highly length of channels (FDQ series).

All categories support microclimate in two ways: Observing exactly the set parameters in the local area or reaching approximately general values \u200b\u200baround the room. In addition, channel air conditioners have a number of additional benefits:

  • noise reduction mode of both blocks;
  • electronic power control;
  • swinging rotor for contact with harmless refrigerant;
  • anti-flap filter;
  • automatic control of normal air humidity;
  • functions of self-diagnosis, night savings and lacking / presence of people indoors;
  • anticorrosive processing of materials.

This is not all specific characteristics and functions of daikin daikin air conditioners. Each series and models can be additional features. But a special plus is a multisystem layout that reduces the number of external appliances, while maintaining the appearance of the building and saves a place, since it is not always possible to accommodate several external blocks.

It is necessary to accurately calculate the length of the track so that the freon is normal to reach the indoor unit, to properly design the system to avoid excessive air supply in one air ducts and insufficient. It is also necessary to thoroughly fix the ducts and select qualitative material For them, otherwise expensive equipment will publish outsided noises.

Industrial systems Daikin

The most important distinctive trait Industrial air conditioners Daikin are their power, the values \u200b\u200bof which start from 7 kW and reach huge values. Install such equipment in institutions with a large area and having strict requirements relative to supported air parameters - medical laboratories, server, storage facilities, banks, and so on.

Daikin has all industrial air conditioners perfectly hold the desired temperature, the humidity level and make it possible to make the settings before. The lineup includes roof air conditioners (UATYQ-C series), screw (Ewad-TZ series) inverter Daikin air conditioners (EWAD-AJYNN / S series), wardrobe installations (UCPJ series), operating only for cooling, but with excellent characteristics Cooling capacity up to 189 kW, multi-zonal VRV and VRF systems and other high-tech equipment.

By the way, the roof monoblocks are an inexpensive option for large-scale rooms of the type of shopping centers and universal shops. Even plus - simple installation, carried out on the roof or next to the building itself. It provides for energy saving with natural cooling into transition seasons - the outer air is used for cooling inside, and this saves electricity consumption.

Precision Daikin systems

When it comes to maintaining the temperature in the server (data center), then Daikin air conditioners can be translated into the disconnect date. They are installed where it is important to create conditions up to tenths of degrees and a deviation at moisture marks not more than 2.5%, as well as to adjust the content of harmful microparticles in the air at a continuous production process.

All precision air conditioners from Daikin are divided into devices:

  • with air cooled coolant - consist of an internal unit with the main nodes of the device, and the outdoor (remote), installed outside the room;
  • water cooler coolant - consist of one block with a water capacitor located inside, the heating mode performs a built-in electrical heater, and not a heat pump;
  • with mixed cooler cooler - It has 2 contours: freon and water, the principle of operation of which is to transmitting heat from the first to the second, and in turn, watering through the external heat exchanger displays the overaction of heat.

The first two species are single-mounted unlike the latter.

In some series, Daikin's roof air conditioners are equipped with a "Free Cooling" control system, which, when lowering the ° T °, \u200b\u200buses its cold flows coming through the air ducts for internal cooling. This considerably saves power consumption.

The air conditioner is precision Daikin for the server can be different methods Air supply: upper and lower. In the first embodiment, the transmission goes through the air conditioner itself and ceiling ducts, and in the second - by means of air distributors from the raised floor.

Additional advantages of air conditioners for the server from Daikin, judging by the reviews, can be attributed to:

  • fan power, which exceeds standard quantities in three-time;
  • a huge range of working T ° - from -45 ° to + 50 ° on the street (the remaining industrial limit is -15 °);
  • high productivity on cold reaching 300 kW in some models;
  • support for accurate specified parameters in the built-in microprocessor;
  • 24-hour and year-round uninterrupted operation of the system.

All industrial climatic systems from Daikin are characterized by long-term operation without breakdowns. But at the same time, several conditions must be observed: accurate design, taking into account all the characteristics of the building, the installation of only experienced specialists and regular service.

When designing in case of failure of the equipment, it is necessary to provide at least 50% redundancy and the system of immediate alerts about failures.

External and internal blocks for multi-split systems and VRV systems

As mentioned earlier, Daikin produces separate series of outdoor and internal blocks that may have different layout options among themselves in multi- and VRV-systems.

As an example, you can bring the system "Super Multi Plus", which is designed to install in cottages, large apartments, salons, that is, where there is a small group of rooms. External blocks of the Daikin air conditioner from this series have a cold capacity from 11.2 kW to 15.5 kW and combined with internal blocks of the SPLIT class and SKYAIR. In this case, the external unit of such a Daikin air conditioner can be combined with 9 internal in one system.

There are also a number of internal devices. of different typeswhich are suitable for working with external MXS multicist.

This extends the boundaries of the choice of equipment, and also makes it possible to solve complex technical tasks.

Instructions for the console Daikin

Like all other manufacturers, Daikin has operating instructions for all series and air conditioners. They include standard set Recommendations for the operation, descriptions of performance and additional options, installation councils and, of course, detailed instructions To the Daikin air conditioner console with all the rules for installing various modes.

It can be said that the last item is one of the most important, since there are given detailed installations To set the main modes of cooling, heating, drying, ventilation and purification. The instruction on the control panel of the air conditioner Daikin explains how to enable the "timer" function, how to adjust the air flow or enable economical mode.

The main instruction to the air-conditioned Daikin also contains important information On cases of faults that are not impaired work. For example, if the operation is suddenly stopped and the "Operation" light lights up, this means the triggering of the protective stop of the device with significant voltage fluctuations. Usually the resumption occurs after 3 minutes.

Daikin air conditioners error codes

Also, the instructions for the air conditioner Daikin console has important information about malfunction codes that require urgent contact with service services. Otherwise, they are called error codes from Daikin air conditioners, which are divided into errors:

  • systems;
  • internal block;
  • outdoor unit.

All Daikin air conditioners errors have their alphanumeric designation, that is, the code. For example, the consoles for Daikin air conditioners or the FTK20GV1B model of the FTK20GV1B device showing the U0 error talk about the lack of refrigerant.

When buying it is necessary to immediately check the equipment of the acquired technology and the availability of instructions.

Instructions on the following models:

Daikin FTX20JV / RX20JV

Air conditioning Daikin. FTX20JV / RX20JV

Table of contents
Disposal
Name of each part
Preparation before starting work
Selection of work modes
Additional modes and settings
Useful advice
Cleaning your air conditioner
If it seems to you that there is a malfunction
When it will not be used for a long time (at the end of the season of use)
Place of installation and electrical work
Precautionary measures

Disposal
For the manufacture of this device, materials that can be used are reused. Therefore, learn from local authorities, how to properly dispose of it in your region.

Name of each part
External block

1 - Air fence is made on the back and side surfaces.
2 - Air output on the front surface, behind the bars is a fan and heat exchanger.

Internal block

1 - Air fence to the internal block.
2 - Telephone reception window, indicator lights.
3 - Air emission from the indoor unit.

Remote controller remote control

1 - Running energy saving mode.
2 - Turbo fan mode.
3 - setting the desired temperature.
4 - Selecting a mode of operation.
5 - Switching fan operation modes.
6 - Enabling-disconnecting the device.
7 - position of the partition.
8 - Running comfort mode.
9 - Timer control buttons (turn on-shutdown, time setting, reset timer, reset all settings).

Preparation before starting work
Installation and connection of the device should produce specialists with the experience of appropriate work.
Install the batteries in the remote control.
Connect the air conditioning to the power supply through the socket of the desired nominal, with grounding.
Ensure that there are no obstacles to the movement of air around the external and internal blocks.

Selection of work modes
Daikin FTX20JV / RX20JV air conditioner model supports the following operation modes:
auto-break;
heating;
cooling;
drainage;
ventilation.
In auto-break mode, air conditioner supports temperature within the boundaries you specified. If it became colder, heating is turned on if it became warmer - cooling.
Heating mode is suitable in the cool season. Keep in the mind that in this mode it is possible to frost an external unit, so the work will be periodically suspended (no more than 10 minutes) to defrost the external block. In addition, the start of the fan can not occur immediately after pressing the button on the remote. So the protection against blowing with cold air is working - the heat exchanger is warmed first, and only then the fan is turned on.
In cooling mode, air conditioner cools the air and dries. The temperature is maintained at the level specified by you.
In the drainage mode, the electronics works in such a way as to withdraw from the air moisture at the same time with the minimum affecting the temperature in the room.
In ventilation mode, air circulation is maintained.

Additional modes and settings
For more efficient cooling and heating of the room, you can use the turbo fan operation mode.
For work at night, a dream mode is provided. In it, air conditioning works quieter.
Econocool mode is provided for energy saving. In this mode, the air conditioner consumes less energy.
Automatic restart. If the air conditioner worked any mode and the power is turned off, then after the energy appearance on the network, the operation will automatically continue in the same mode.
Timer - To start and disconnecting the operation of the air conditioner on a schedule, it is possible to configure start and shutdown at a specific time.

Useful advice
Do not transfer the room. This leads to overflowing energy and can harm health.
Close the blinds and curtains indoors so that the sunlight does not heat the items.
A large number of people and working heating devices can also complicate the operation of the air conditioner.
Need to follow the position of the vertical damper. When heated, it should be vertical when cooling is horizontal.
Watch out for the cleanliness of the air filter. The dirty filter will make it difficult to work the air conditioner.
Make sure that the windows and doors are closed during cooling. Do not forget to periodically ventilate in the room - the air conditioner cools, but does not update the air.
At first, work is to cool the room faster, it is recommended to include the operation mode of the turbo fan.
Cleaning your air conditioner
Do not touch the metal parts with bare hands. Disconnect the air conditioner from the network with dry and clean hands.
Use only pre-dissolved detergents in the water.
Do not use detergents with abrasive particles, gasoline, solvents, hot water. All this can damage appearance plastic.

If it seems to you that there is a malfunction
Air conditioning does not work. Check if the plug is connected to the outlet. Are there food online. Does not disconnect the operation of the air conditioner Timer shutdown.
Unable to turn on the air conditioner 3 minutes after it is turned off. This is protection against frequent launches. Wait 3 minutes and try again.
During drying, the fan of the indoor unit is turned off. During operation in this mode, the electronics ensures that the room has happened, the minimum air cooling occurred. Also, it is necessary to disrupt condensate from the active zone.
During operation in heating mode, stop (maximum 10 minutes) of the internal block operation. This is necessary to defrost the external block, which in this mode is covered with ice.
During the start of the heating mode, the internal unit begins to work not immediately. First heat exchanger heats up, and then the fan turns on - it protects you from blowing cold air.
After the emergence of nutrition in the power grid, the air conditioner began to work, although nobody managed to them from the remote control. If the air conditioner worked in any mode before the emergency breakage, then after the power appears, it will automatically resume work in the same mode.
From the external block the water flows. During cooling and heating in the air conditioner there are elements of the cold environment. Condensate can be formed on them. If, during the heating of the room, ice appeared on the external block, the water will appear during the thawing.
From the outdoor unit goes white smoke. During heating, the air conditioner removes cold air into the street, around which fog can be formed.
The image on the remote control has become worse, disappeared, the remote control does not work. Check for the presence and correctness of the installation of batteries. If necessary, replace them.
It fails to heat / cool the room properly. This may be associated with a number of reasons. Check if the mode of operation is correctly selected, the power of the fan. Whether windows and doors indoors are closed, there are no working heating devices. If there are many people in the room, then cooling work will go slower. Isn't Pollution on Air Filters?
In the air conditioner outgoing a strange smell. Are the air filters clean? Is there no pollution inside the air cavity? Perhaps the smell is tightened from outside, for example, from carpet or wall. This is especially possible when condensate and mold growth come across them.
Cracked cracks during the operation of the air conditioner. Temperature fluctuations cause a change in the size of the plastic and the appearance of a cod.
It is heard splashing, bouffaging. This is possible when the refrigerant movement, condensate. If the air conditioner is turned off, and there are sounds, it is possible that it is associated with the work of exhaust ventilation - the air into the room will come through the hose to remove condensate.

When air conditioning will not be used for a long time
If you plan for some time not to use air conditioning, it is recommended to prepare it to it.
Turn it in heating mode. It dries the inner block and stop the growth of fungi and bacteria.
Disconnect the plug from the outlet.
Remove the batteries from the remote control.
For use after a long period without use, it is necessary:
Make sure there are no obstacles to air movement near both blocks;
Install the batteries in the remote control;
Connect the plug to the rosette of the corresponding nominal;
check for grounding;

Place of installation and electrical work
Installation work must be carried out by specialists with experience of such work.
You should not install the device in places where many machine oil, salt wet climate, in the atmosphere there is hydrogen sulfide or combustible gases.
You can not accommodate air conditioning next to the high-frequency equipment.
Do not place the device where the air outlet from it will be blocked.

Precautionary measures
You can not connect the device to carry, extension, the outlet of the inadequate power.
It is forbidden to modify, change, repair the power wire and.
It is impossible to put heavy, solid, hot items on the power wire, do not put foreign objects on the internal and external blocks.
You can not pull the plug from the outlet during the operation of the air conditioner. First disconnect it using the remote.
Do not expose people, animals and plants to long-term exposure to the flow of cold air - it can harm health.
You can not insert fingers, pencils and other items in the technological holes of the air conditioner housing. This is fraught with injury.
If the air conditioner is found in the process of the air conditioner, such as an unusual noise, the smell of burned - stop working, disconnect the plug from the outlet and call the technical assistance.
If the air conditioner stopped heating and cool, then you need to make sure there is no refrigerant leakage. Call specialists.
Do not spray combustible substances on the internal and external blocks - this can lead to a fire.
Do not put electrical appliances and furniture under the inner block - it is possible to release condensate, which will spoil the property.
Cleaning the device must be performed when the fork is disconnected from the outlet.
Regularly ventilate in the room, because the air conditioner does not update the air, but only cool / heats it.
During thunderstorms, disconnect the air conditioning from the power supply.
Ground the device properly.

Comfortable air conditioning

CompaniesDaikin.

USER'S MANUAL

Models:FTX25 JV1 NB. Ftk.25 JV1 NB.

FTX35JV1NB ftk35jv1nb.

Necessary information

n Precautions ............................................................. ............................................

Internal block .................................................. ..................................................

Replacing highly efficient air-reading filters

· Highly efficient filters need regular replacement.

1. Open the front panel

2. Remove the air filters

3. Disconnect the filter element and insert the new

4. Secure the new air purifying filter

5. Insert air-reading filters and filter block into place, close the front panel

(Press the front panel in three places - along the edges and in the center.)

Comment:

q To acquire air-reading filters, contact the firm in which you purchased air conditioning.

q When a high-performance filter filter element is dirty, it can no longer be used, and is subject to replacement.

q Operation of the air conditioner with contaminated air purity filters leads to insufficient air purification entering the room, insufficient air cooling and penetration into the placement of foreign odors.

q Perform the filter replacement if:

· Does not clean the air indoor;

· Insufficient cooling;

· You smell from the air conditioner.

Name of components

Highly efficient air purification filter (with frame)

Highly efficient air purifying filter (without frame)

Cleaning facial panel

To clean the front panel it must be removed.

Attention!

· Use a strong steady stool to remove or install the front panel.

· When removing and installing the panel, you securely hold it and do not drop on the floor.

· Do not use water having a temperature above 40 ° C, gasoline, kerosene, solvents or other chemicals, as well as abrasive materials.

· Upon completion, check the panel and make sure it is securely fixed.

1. Raise the front panel of the indoor unit

· Take behind the paws on the side sides of the panel, and lift it until the click, and the panel will not lock in the raised position (the angle of the lift is about 60 o).

2. Remove the front panel

· Supporting one hand panel, the other hand slide down its retainer.

· Both hands pull the grille on yourself and remove it.

3. Clean the dirt panel

· You can wipe it with a soft cloth moistened in water.

· You can use a solution of a neutral detergent.

· Grid can be washed with water. After washing, it is necessary to wipe with a dry cloth and dry, not allowing direct sunlight.

4. Put the panel

· Insert the three mounts of the panel to the corresponding sockets and evenly press the grille to the block.

· Supporting a grid with one hand, the other hand slide the retainer up.

· Slowly dropping the grille, return it to its original position. (Press the grille in three places - along the edges and in the center.)

Check operations

Check if the foundation and fastening of the external block are enough; Will he be able to fall and is not subject to corrosion block.

Make sure there are no cliffs and damages that ground the wires of the wires.

Check if there are objects that interfer air input into the external and internal blocks of the air conditioner or air output.

Ensure that both when cooled and when the water is heated freely flows out of the drainage tube.

If water does not flow from the drainage tube, it may be dripping from the indoor unit. In this case, turn off the air conditioner and consult a specialist.

Operations preceding the shutdown of the air conditioner for a long period

1. To dry the internal space of the air conditioner, select a good day, move the air conditioner to the mode at which only the fan works, and let it work for a few hours.

Air conditioning is translated into fan operation as follows.

< Ftk.>

1.

2. Press the button.

H.>

1. Click the button and select "".

2. Click the button and set the temperature of the 32 ° C.

3. Press the button.

· Airflow speed will be automatically installed.

· This operation should be carried out when the air temperature in the room does not exceed 28 ° C.

2. Spend air filters and insert them into place.

3. Remove the batteries from the remote control.

4. Turn off the air conditioner.

Regular maintenance of air conditioner

Under some conditions, as a result of the operation of the air conditioner for several seasons, its internal surfaces can be strongly polluted, which leads to a deterioration of its characteristics. Therefore, in addition to regular care for air conditioning, we recommend calling a specialist to inspect it from time to time. To this end, it is necessary to contact representatives of the company in which air conditioning was purchased.

Diagnostics of faults

Signs that do not testify to breakage

The situation listed below are not associated with a malfunction or breakage of the air conditioner, but have other reasons. Therefore, in these cases, the operation of the air conditioner can be continued.

Symptom

Cause

Air conditioning is not immediately starting to work.

· The power button was pressed shortly after the air conditioner was turned off.

· A new mode of operation was selected.

· Run delay serves to protect the air conditioner. Wait about 3 minutes.

Air conditioning is not immediately after turning on the heating begins to feed warm air room.

· Air conditioner heat exchanger warms up. Wait from 1 to 4 minutes. (Air supply to the room begins only after it reaches a certain temperature.)

Work on heating is stopped, and the sound of the flowing fluid is heard from the air conditioner.

· The system automatically switched to the defrosting mode of the external unit. Wait from 3 to 8 minutes.

From the external block, water drips or steam expires

n In heating mode:

· When defrosting the ice melted and forms water or steam.

n in cooling or drying modes:

Easy fog comes out of the indoor unit.

· In the cooling mode, the moisture contained in the air is condensed and in the form of a fog is made from the air conditioner with a cold air flow.

You smell from the inner block.

· Smells of furniture, tobacco smoke, etc., are absorbed by the inner block, and then enter the room with an air flow. (In such cases, it is recommended to refer to a specialist who promotes the inner surfaces of the air conditioner.

The fan of the external block rotates, although the air conditioner does not work

n Immediately after turning off the air conditioner:

· The external block fan must rotate for 30 ° C after shutdown.

n When the air conditioner did not work long time:

· At high air temperature, the external block fan starts automatically to avoid system damage.

The operation of the air conditioner is suddenly stopped (but the lamp work glows)

· The system can automatically turn off at strong power voltage fluctuations. It will turn on for about 3 minutes again.

Checks preceding a specialist call

Before contacting the repair and maintenance of air conditioners, once again spend the following checks.

Symptom

Check

Air conditioning does not work (the work lamp does not shine)

· Is the circuit breaker is not disconnected? Is the fuse not burned?

· Is there no power failure?

· Are batteries inserted into the remote control?

· Is the remote control address switch to the correct position? (See section Preparation of air conditioner to work.)

Is time set correctly on the timer?

Cooling or heating is insufficient

· Are the temperature of the air indoor given from the console?

· Are windows and doors closed?

Is the speed and direction of the air flow correctly adjusted?

Air conditioner work suddenly stops (work lamp flashes)

· Are air filters not polluted?

· Are there any obstacles to air input to external and internal blocks or air outputs from them?

Clean the air films or remove obstacles. Turn off the power using the circuit breaker, and then turn it on again. After that, try running the air conditioner from the remote control. If the work lamp continues to flash, call a specialist from the company you can find the air conditioner.

Failures occur in the air conditioner

Failures in the operation of the air conditioner can be caused by lightning discharges or powerful radio waves. Turn off the power, and then turn it on again. After that, try running the air conditioner from the remote control.

Cases requiring immediate challenge

Dangerously!

n If something that causing a suspicion is happening with the working air conditioner, for example, the smell of Gary appears - turn off the air conditioner and turn off the power.

Continuation of the operation of the air conditioner in such cases can lead to severe consequences - electric shock or fire.

n Do not attempt to repair or redo the air conditioner

Otherwise, electric shock is possible or fire.

Contact your company representative to make you air conditioning.

In the cases listed below, you must immediately cause air conditioners.

n. Power cable overheats or damaged.

n. Unusual sounds are heard from the working air conditioner.

n Frequently the automatic circuit breaker is triggered, the fuse cuts out or the leakage protection device is triggered.

n. Switches or control buttons do not work.

n. Feeling the smell of Gary.

n. From the inner block flows water.

Click the OFF button and call the service service.

n. After the power failure:

wait about 3 minutes, and the air conditioner will automatically resume work.

n. During thunderstorms:

If there is a possibility of lightning, turn off the air conditioner and turn off the power. So you protect the device from damage.

qualified specialists.

Under some conditions, as a result of the operation of the air conditioner for several seasons, its inner surfaces can be strongly polluted, which leads to a deterioration of the characteristics of the device. Therefore, in addition to regular care for air conditioning, we recommend from time to time to call a specialist for its inspection. To this end, it is necessary to contact representatives of the company in which air conditioning was purchased. The cost of servicing the air conditioner in this case is its owner.

Fault diagnostics with control panel.

Description

Description

System- ma.

Fine

Outdoor block

Compressor overload

Low pressure in the system

Blocking, overload of the Mo Torah Compress Sora

Low voltage in the network

The input voltage sensor is blocked

Switching error between blocks

Failure of the outdoor unit temperature sensor

In- renny block

Heat exchanger malfunction

Heat exchanger does not work (TH2 -TerModat chick)

Motor lock due to overload

Thermistor of the gas pipe is not working

C4 0r C5.

Heat exchanger does not work

Increased Radia Torah Torah Power Transistor

The terms of air fence does not work

Malfunction of the thermistor of the Ra diator of the Power Transistor